7-44 Chapter 7: Programming Guide
Reverse Feed n Dots
ASCII: GS NAK n
Hexadecimal: 1D 15 n
Decimal: 29 21 n
Value of n: n dots at 1/72 inch
Range of n : 0 – 127
A756 Emulation Mode
0 – 255
A758 Native Mode
Reverses the paper feed in the slip station by n dots at 1/72 inch (NCR
7150™ command). This command is ignored if receipt station is
selected.
Set Horizontal and Vertical Minimum Motion Units
ASCII: GS P x y
Hexadecimal: 1D 50 x y
Decimal: 29 80 x y
Value of x: Horizontal
Value of y: Vertical
Range of x: 0 – 255
Range of y: 0-255
Default: of x: 203
Default: of y: 203
Sets the horizontal and vertical motion units to 1/x inch and 1/y inch
respectively.
When x or y is set to 0, the default setting for that motion unit is used.
The default horizontal motion is x = 203.