A758 Owner’s Guide Chapter 7: Programming Guide
September 1999 126
Reverse Feed
n
Dots
ASCII
:GS NAK
n
Hexadecimal
: 1D 15
n
Decimal:
29 21
n
Value of
n
:
n
dots at 1/72 inch
Range of
n
: 0 – 127 A756 Emulation Mode
0 – 255 A758 Native Mode
Reverses the paper feed in the slip station by
n
dots at 1/72 inch (Axiohm 7150™
command). This command is ignored if receipt station is selected.
Set Horizontal and Vertical Minimum Motion Units
ASCII:
GS P
x
y
Hexadecimal:
1D 50
x y
Decimal:
29 80
x
y
Value of
x
:
Horizontal
Value of
y
:Vertical
Range of
x
:
0 – 255
Range of
y
:
0-255
Default: of
x
:
203
Default: of
y
:
203
Sets the horizontal and vertical motion units to 1/
x
inch and 1/
y
inch
respectively.
When
x
or
y
is set to 0, the default setting for that motion unit is used.
The default horizontal motion is
x
= 203.