Chapter 3: In-Place MICR Adjustment 23
For single-board printers (the MICR adjustment pots are visible
from the front), raise the front cover and remove both screws as
shown above that are securing the plastic trim to the steel frame.
Unlatch the restraining tab on the right, inside edge of the cover.
Separate the plastic cover trim from the metal frame and set the
trim aside. Close the metal frame.
For dual-board printers, remove the printer’s top cover. For more
information, see the 7156 Service Guide.
If you accidentally move the print head carriage before or during
the adjustment, reset the printer to accurately position the print
head carriage.